| >> DASTU |
|
 |
The model MECH DASTU is designed for collection, storage and transmission of data from field instruments and control room and MCC.
The MECH DASTU will operate in harsh environment and have capability to collect and storage data and also having facility for local retrieval of data using RS-232 serial interface. |
|
|
| |
MECH DASTU can be powered with 12Vdc Hybrid (mains and Solar) power source so in case of power failure DASTU works without failure.
Facility for internal backup for one year data collection and storage without applying external power so that in case of communication failure / power failure data will not be lost.
Analog / Digital input can be configured |
|
| Applications : |
-
Collection of data from field instruments like Rain sensor, River level sensors, Flow meters, Automatic Whether Stations, etc.
- Measurement of Lake level, Flow, etc.
-
Provides Reliable VHF / UHF Data links for serial (RS -232) Communications with remote instruments.
- Appropriate for multiple- access network applications or simple point to point links
-
Provides robust, economical point to multi point data links for SCADA installations for Dams and Canals
|
|
| Features : |
|
| Click here To know more / To download the brochure. |
|
|
|
| |
|
|
| |
| >>Remote Modem Link. (RML) |
|
 |
The MECH Remote Modem Link converts RS-232 data. The transmission on UHF / VHF is effected by FSK modulation
The model MECH RML is designed for transmission of data from field instruments and control rooms
12 VDC hybrid power is generally utilized for continuous operation of RML under mains power failure
|
|
|
| |
|
|
| |
|
|
| |
| >>Tele-transmitting Rain gauge stations |
 |
This unit is designed for collection, storage and transmission of Rainfall data from remote Stations to control room.
Rainfall for current hour, Today’s, Yesterday’s and from defined date of start of mansoon (Generally 1st of June), Atmospheric temperature is continuously displayed.
Operate in harsh environment. and having facility for local retrieval of data using RS-232 serial interface
Powered with 12Vdc Hybrid (mains and Solar) power source so in case of power failure it works continuously. Facility for
|
|
|
| |
internal hourly data backup for one year without applying external power so that in case of power failure data will not be lost.
Online rainfall data for 365 days is made available at control room without manual intervention for further analysis & Control. |
|
| Applications : |
|
|
| Features : |
| |
| Click here To know more / To download the brochure. |
|
|
| |
|
|
| |
| >>Ultrasonic Water Level Recorder |
 |
The model MECH UWLR is designed for collection, storage, transmission and printing of levels
The MECH UWLR will operate in harsh environment and have capability to collect, store, transmit and print current / stored data and also having facility for local retrieval of data using RS-232 serial interface
MECH UWLR can be powered with 12Vdc Hybrid (mains and Solar) power source so in case of power failure UWLR works without failure.
|
|
|
| |
Optional facility for internal hourly data backup for one year without applying external power. |
|
| Applications : |
- Measurement of Lake level, Content, etc.
- Measurement of River level, Discharge
- Measurement of ESR & GSR levels
- Measurement of levels and flow in Canal
|
|
| Features : |
|
| Click here To know more / To download the brochure. |
|
|
| |
|
|
| |
| >>Power Supply (Mains/Solar/Hybrid) |
|
|
|
| |
>>Mains |
|
| |
The model MECH OBC is designed to deliver power line isolated Uninterruptable power for precision instrumentation systems. The MECH OBC will operate in harsh environments.
The primary function of the charger is to maintain a lead acid battery in a temperature compensated floating fully charged state. When maintained in this state, lead acid batteries can have a useful life of many years. Battery life decreases with repeated discharge cycles and increasing depth of discharge. When the charger looses input power, and there is no auxiliary-charging source is active, external equipment draws power from the battery. When input power is restored, the battery charges the appropriate rate until it is completely charged, at which |
|
| |
|
| Applications : |
- Battery charger for 12V SMF batteries from 1-80 A.H.
-
Electronic equipment requiring isolated DC power not subject to disturbances or disruptions.
- Supervisory Control & Data Acquisition (SCADA) RTUs and communication equipment..
-
Systems requiring Uninterruptable DC power, where AC power is available for battery charging.
-
Process metering and billing equipment requiring continuous power for measurement integration
|
|
| Features : |
|
| Click here To know more / To download the brochure. |
|
|
| |
|
|
| |
>>Solar |
|
| |
The model MECH OBCS is designed to deliver power line isolated uninterruptable power for precision instrumentation systems using an alternate energy source, such as solar panel. Alternate power sources are ideal for low power instrumentation systems at remote monitoring sites where commercial power lines are not available. Most of the alternate energy sources can be directly connected to the charger input. The MECH OBCS will operate in harsh environments, and has unique capabilities for remote power system monitoring, a cost saving feature for remote system installations.
The primary function of the MECH OBCS is to maintain a SMF battery in a temperature compensated floating fully charged state. When maintained in this state, SMF batteries can have a useful life of many years. Battery life decreases with repeated discharge cycles and increasing depth of discharge. The most common alternate energy source, the photovoltaic panel, provides durinal charging. Therefore, the objective is to size the battery and load so that only a minor portion of the battery capacity is consumed overnight, avoiding deep discharges. The MECH OBCS charges the battery as efficiently as possible while the charge input is active, without overcharging the battery. Overcharging will drastically reduce battery life.
When the alternate power source is not producing power, the external equipment draws energy from the battery. When input power is restored, the battery charges at the appropriate rate until it is completely charged, at which time the charger switches to the float mode. |
|
| |
|
| Applications : |
- Systems requiring Uninterruptable DC power, using an alternate energy source, typically solar
- Electronic equipment requiring isolated DC power not subject to disturbances or disruptions
- Supervisory Control & Data Acquisition (SCADA) RTUs and communication equipment
- Battery charger for 12V SMF batteries from 1-80 Ah with on-line load
- Redundant charging option using a solar panel to back up long term AC power outages
- Process metering and billing equipment requiring continuous power for measurement integration
|
|
| Features : |
- MECH OBCS delivers 8 A of output current at 12VDC
- Versatile charger input ranges 12-20 VDC.
- Charge level monitor provides an indication of the battery charge, battery low on LED.
- Power failure indication on LED with potential free contact.
- Reverse polarity indication for output.
- Output over load protection.
- Over voltage protection for Input and Output.
|
| Click here To know more / To download the brochure. |
|
|
| |
|
|
| |
>>Hybrid |
|
| |
The model MECH OBCH supplies line isolated Uninteruptable power for precision instrumentation systems.
The MECH OBCH is designed tol operate in harsh environments, and has unique capabilities for remote power system monitoring, a cost saving feature for remote system installations
The universal AC input uses an IEC power entry module allowing easy input configuration for mains. Auxiliary charger input is also available to accept lower voltage AC or DC inputs as an optional backup for long term AC outages. The dual inputs are beneficial at remote project sites. A solar panel is directly connected to the auxiliary charger input
The primary function of the MECH OBCH is to maintain a SMF battery in a temperature compensated floating fully charged state. When maintained in this state, SMF batteries can have a useful life of many years. Battery life decreases with repeated discharge cycles and increasing depth of discharge.
When charger looses input power, and there is no auxiliary-charging source is active, the external equipment draws energy from the battery. When input power is restored, the battery charges at the appropriate rate until it is completely charged, at which time the charger switches to the float mode. |
|
| |
|
| Applications : |
- Suitable for electronic equipment requiring isolated DC power not subject to disturbances or disruptions.
- System requiring Uninteruptable DC power , where AC power is available for battery charging
- Supervisory Control & Data Acquisition (SCADA) RTUs and communication equipment..
- Battery charger for 12V SMF batteries from 1-80 Ah with on-line load.
- Redundant charging option using a solar panel to back up long term AC power outages
-
Process metering and billing equipment requiring continuous power for measurement integration
|
|
| Features : |
- MECH OBCH delivers 10 A of output current at 12VDC
- Simultaneous dual charger inputs: 230 VAC and /or low voltage AC/DC.
- Multi mode intelligent charge regulator provides temperature compensated charging for selected battery capacity.
- Charge level monitor provides an indication of the battery charge, battery low on LED.
- Power failure indication on LED with potential free contact.
- Safety under reverse polarity and indication for output.
- Output overload protection.
- Over voltage protection for Input and Output.
|
| Click here To know more / To download the brochure. |
|
|
| |
|
|
| |
| >>SCADA Software and HMI |
 |
The MECH SCADA /MMI Software is a complete automation solution providing graphical visualization, Data acquisition and Supervisory Control for field instrumentation program.
The MECH SCADA system is comprises of host software automation solutions including remote telemetry systems, remote terminal units (RTU), programmable logic controllers(PLCs) which are typically installed in remote areas. |
|
|
| |
Communication is over long distances to the host system.
Objects in the picture are linked to specific measurement or control data in the database to allow viewing of real time data. The objects are also animated to show, for example, the level of water in a Reservoir, Weir, Canal level or flow, Tank or the position of gate or valve. In addition, multiple colors are used to show whether the parameter is in or out of alarm condition.
In addition to providing real time data, several tools are included for viewing historical data and generating reports.
An event scheduler is provided for performing tasks at specific times, such as generating & Printing reports. |
|
| Applications : |
- Configure, monitor and control Remote Terminal Unit (RTU)
- Control and monitoring of Dams, Canals, Tanks
- Flood forecasting, Flood warning and Flood routing
- Water storage and distribution monitoring
- Water supply Control and Management
- Hydro operations----- Flow monitoring, release and diversion control for canal networks
- Flow metering at remote sites
- Process monitoring and Control-------- Irrigation / Hydro electric projects, Thermal power stations, Remote fire detection systems
- Vehicle tracking and fleet management systems
|
|
| Features : |
- Data collection, validation, encryption, logging, storage, and management
- Real time and historical trend curves.
- Alarm Annunciation
- Supervisory Control
- User friendly GUI / MMI
- Data access over LAN / WAN.
- Field configuration facility for any combination of analog and digital inputs.
- Detailed Event and Status reports.
- Hierarchical security for Viewing and Control.
- Compatibility with VHF / UHF / GSM / VSAT telemetry networks
- Adaptable to sufficient instrument standard analog input
|
| Click here To know more / To download the brochure. |
|
|
| |
|
|
| |
| >>Control Consoles for Hoist Motors |
 |
The MECH control console is a complete control solution that provides local / auto Control for your field instrumentation.
The MECH control console comprises of Switch gears, Push Buttons, Indicators, Safety fuses, Single phasing preventer, Auto / Manual selection facility, Ammeter, Voltmeter, ELCB, MCB, digital status monitor & control wiring compatible with DASTU
The MCC provides a user-friendly operation for any type of load(s).
Provides out put Overload protection with indication on front panel & Interlocking for auto manual operation with variable control voltages |
|
|
| |
|
| Applications : |
- MECH Control Console (MCC) for operation of Hoist Motors.
- MECH Control Console (MCC) for operation of Vertical Turbine Pump.
- MECH Control Console (MCC) for distributing Electrical loads.
|
|
| Features : |
- Fully Compatible with DASTU for Remote / Local operation from Personal Computer.
- Remote and/or Local Auto / Manual Mode selection facility
- Equipped with Single phasing preventer and safety fuses.
- Digital display of status
- Overload protection with indication on front panel.
- Protection for dry pumping , priming failure, vibration, temperature, under / over voltage
- Variable control voltages.
- Local / Field operation facility
- Interlocking for auto / manual operation.
- Space Heaters, illuminating lamp.
- Cable glands for cable entry at bottom
|
| Click here To know more / To download the brochure. |
|
|
| |
|
|
|